Home » Miniature
Circuit Breakers
Miniature Circuit Breakers
Newtech MCB's are among the best available
designed with proven, trusted and reliable German Technology to provide
enhanced operating safety, Installations for domestic, commercial and
industrial applications. Some of the salient features of these MCB's are as
below.
Construction :
Miniature Circuit Breakers are housed in injection
moulded flame retardant, high strength thermo plastic material having high
melting point, high dielectric strength and temperature with stand.
Trip free Mechanism i.e. the breaker trips internally even if the operating
knob is held in ON position.
The Tripping Mechanism is thermal magnetic type :
» Finger Protection
MCB's are finger protected to IP 20 as per IS : 8828 : 1996 the live
current carrying parts cannot be touched accidentially.
» Magnetic Protection
When overload values exceed the value specified for different
characteristic curves i.e. B & C strong Magnetic field is induced which
results into instantaneous tripping of MCB.
» Effective Quenching
Arc produced of contacts is rapidly pushed Magnetically into a 12 plates
arc chamber where it is broken down effectively & cooled.
» Trip Free Mechanism
Trip free Mechanism ensure tripping of MCB even if the knob is kept in 'ON'
position.
» Special Silver Alloy Contacts
The contacts are made out of special silver alloy inlaid strips which gives
low contact resistance resulting in low voltage drop & hence very low
power consumption and temperature rise. These contacts have very excellent
anti weld properties.
» Thermal Protection
Small overloads are detected by fine calibrated Bimetal which deflects if
the current is greater than the rated current and hence tripping the MCB.
» Dual Termination
The incoming terminals are designed for termination of Busbar as well as
cable individually or simultaneously. Terminals are suitable for Cables upto
25mm².
Housing
The housing of Newtech 10KA MCB is injection moulded
from Special grade 30% GF, fire retardant UL94, V-O Polyester which is
anti-tracking and non-Hygroscopic and can withstand high temperature.
Current Limiting Design
The current limiting design does not allow fault
current to reach its peak |k/2 & cut it at a very low value (ld). This
keeps let through energy very low which enables MCB to clear short circuit
breaking capacity of 10KA effectively.
Salient Features :
- Breaking capacity 10KA for 'B' and 'C' curve.
- Trip free mechanism, if Knob is kept in 'ON' position.
- Dual termination for busabr as well as cable connection.
- Consistency in tripping characteristics.
- Special alloy contacts.
- "Finger Safe" Terminals - IP 20 degree of protection.
- Thermal as well as magnetic release.
Technical Information
 |
| S.no |
Rating |
Newtech MCB's Power Loss (Watts) |
Maximum Permissible power Loss
(Watts) as per IS : 8828/IEC 60898 |
| 1 |
6 |
1.2 |
3.0 |
| 2 |
7.5 |
1.7 |
3.0 |
| 3 |
10 |
2 |
3.0 |
| 4 |
16 |
2.5 |
3.5 |
| 5 |
20 |
3 |
4.5 |
| 6 |
25 |
3.5 |
4.5 |
| 7 |
32 |
4.5 |
6.0 |
| 8 |
40 |
5.5 |
7.5 |
| 9 |
63 |
7.5 |
13 |
|
 |
Comparative Table
 |
| Rating |
B &
C Type MCB's |
| 6-32
A |
40-63
A |
| As Per ISI |
Newtech |
As Per ISI |
Newtech |
| 1.13 In |
Should not trip in 1 hour |
Does not trip in 1 hour |
Should not trip in 1 hour |
Does not trip in 1 hour |
| 1.45 In |
Should trip in 1 hour |
Trips in 30 Min. |
Should trip in 1 hour |
Trips in 30 Min. |
| 1.9 In |
Should trip in 1 hour |
Trips in 30 Min. |
3.0 |
Trips in 30 Min. |
| 2.55 In |
Trips in 60 Sec. |
Trips in 20 Sec. |
Trips in 120 Sec. |
Trips in 30 Sec. |
| 3 In |
"B" Curve should not trips in 0.1 Sec. |
"B" Curve does not trips in 0.1 Sec. |
"B" Curve should not trips in 0.1 Sec. |
"B" Curve does not trips in 0.1 Sec. |
| 5 In |
"B" Curve should trips in 0.1 Sec.
"C" Curve should trips in 0.1 Sec. |
"B" Curve trips in 0.04 Sec.
"C" Curve does not trips in 0.1 Sec. |
"B" Curve trips in 0.1 Sec.
"C" Curve should trips in 0.1 Sec. |
"B" Curve trips in 0.04 Sec.
"C" Curve does not trips in 0.1 Sec. |
| 10 In |
"C" Curve should trips in 0.1 Sec. |
"C" Curve trips in 0.04 Sec. |
"C" Curve should trips in 0.1 Sec. |
"C" Curve trips in 0.04 Sec. |
|
 |
Technical Information
 |
| Standard Conformity |
IS : 8828 : 96 |
| Types/Series |
B |
C |
| Rated Current (In) |
6-63 A |
6-63 A |
| Rated Voltage (AC) (Ue) |
240 / 415 V |
240 / 415 V |
| Rated Frequency (F) |
50 Hz |
50 Hz |
| Nos. of Poles |
*SP, *SPN, * |
DP, *TP, *TPN |
| Rate Short Circuit Breaking Capacity A |
10000 A |
1O000 A |
| Magnetic Release Selling |
(3-5) in |
(5-10)in |
| Rated Insulation Voltage (Ui) V |
500 V |
500 V |
| Electrical / Mechanical Endurance |
- |
- |
| (No, of operations) |
- |
- |
| 1 ess than 32 A |
20,000 |
20,000 |
| More than 32 A |
10,000 |
10,000 |
| Terminal Capacity (max) Sq. mm |
25 |
25 |
| Vibration g |
5 |
5 |
| Shock |
40 mm free fall |
40 mm free fall |
| Protection Class |
IP 20 |
IP 20 |
| Installation Position |
Optional |
Optional |
| Mounting |
Snap Fixing on 35 DIN
Rail |
| Housing |
Moulded Flame
Retardent Thermoplastic Material |
| Current Ratings |
6,8,10,13,
16,20,25,32,40,50,63 |
|
 |
Newtech MCB Selection Chart
 |
| S.no |
Appliances |
Capacity/Approx. Wattage at 240
V Single Phase |
Current Rating of MCB (Amps.) |
Type of MCB |
| 1. |
Air Conditioners |
i) 0.5Ton-775 W |
5 |
C |
| ii) 0.75Ton-upto 1200 W |
7.5 |
C |
| iii) 1 Ton-upto 1.5 kW |
10 |
C |
| iv) 1.5 Ton-upto 2.5 kW |
16 |
C |
| v) 2 Ton-split unit upto 3.5 kW |
20 |
C |
| 2. |
Refrigerator |
i) 165 Ltrs. |
1.5 |
C |
| ii) 285 Ltrs. |
2 |
C |
| iii) 400 Ltrs. |
3 |
C |
| iv) 581 Ltrs. |
5 |
C |
| 3. |
Washing Machine |
i) 300 Watts |
2 |
C |
| ii) 1300 Watts (with heater) |
7.5 |
C |
| iii) 1800 Watts (with heater) |
10 |
C |
| iv) 2200 Watts (with heater) |
16 |
C |
| 4. |
Domestic Pump Set |
i) 0.5 H.P. |
6 |
C |
| ii) 1 H.P. |
10 |
C |
| ii) 2 H.P. |
16 |
C |
| 5. |
Water Heater (Storage or Instaneous
Geyser) |
i) 1 KW |
6 |
C |
| ii) 2 KW |
10 |
B |
| iii) 3 KW |
16 |
B |
| iii) 6 KW |
32 |
B |
| 6. |
Cooking Range |
4500 Watts |
25 |
B |
| 7. |
Oven Cum Griller |
1750 Watts |
10 |
B |
| 8. |
Oven Only |
750 Watts |
6 |
B |
| 9. |
Microwave Oven |
1000 Watts |
6 |
B |
| 10. |
Electric Kettle |
1500 Watts |
10 |
B |
| 11. |
Room Heater |
i) 1000 Watts |
6 |
B |
| ii) 2000 Watts |
10 |
B |
| 12. |
Iron |
i) 750 Watts |
5 |
B |
| ii)1250 Watts |
7.5 |
B |
|
 |